Strange Experience With New Magni Heretic

Discussion in 'Advice Threads' started by JimOfOakCreek, Aug 1, 2023.

  1. JimOfOakCreek

    JimOfOakCreek New

    Banned
    Joined:
    Jul 24, 2017
    Likes Received:
    5
    Trophy Points:
    3
    Location:
    Oak Creek, WI
    I just received my Magni Heretic (B Stock) yesterday. I tried it with my SMSL DAC and it worked perfectly. When I tried it with my Schiit Mani 2 it went into protection mode. My preamp is an Topping Pre90. My headphones are AT M50X with an impedance of 38ohms. I tried tightening the 1/4” adapter on the headphone cable but it was tight as hell. I double checked all connections, RCA, XLR etc. all was good.

    I tried playing an LP again and the Heretic worked fine. It’s been good since. I wonder why it went into protection mode when I started it up initially?
     
  2. scblock

    scblock Friend

    Pyrate
    Joined:
    Nov 11, 2019
    Likes Received:
    1,419
    Trophy Points:
    93
    Location:
    Denver
    • Agreed, ditto, +1 Agreed, ditto, +1 x 2
    • Like Like x 1
    • List
  3. purr1n

    purr1n Desire for betterer is endless.

    Staff Member Pyrate BWC
    Joined:
    Sep 24, 2015
    Likes Received:
    90,119
    Trophy Points:
    113
    Location:
    Padre Island CC TX
    Have found some cheap 1/4" adapters will short momentarily depending upon how cable is oriented / pressure from certain angles. New Heretic has an overcurrent sensor. Possibly is tripped because of that.
     